<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-23 10-10-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 54 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.6 kHz -72 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
31 kHz 74 kHz 9980 52,1343
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,3 dBr 8,13 dBr 8,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 10:10, 23.03.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (53 dBuV) Max at: 74 kHz MIN: 31 kHz % above 76 kHz: 52,1343 Acquired: 2025/03/23 10:09:25 Total samples: 9980 Equivalent time: 0:08:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,4 dBr MIN: 7,3 dBr AVE: 8,13 dBr % above 10,2 dBr: 0,0 Last value: 8,4 dBr (2025/03/23 10:09:25) Station: 96.90 MHz, signal: 4/5 (54 dBuV) 10:03 10:04 10:05 10:06 10:07 10:08 10:09 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality